Written by GLS

Redundant Utility clearance Scotland

We were delighted to be approached by a land owner to clear all disused underground services prior to redevelopment of the 400 acre site. This would then allow the developer to proceed with no unplanned delays from unidentified infrastructure, some of which dates back to the beginning of the 20th century. Over the course of 3 months a substantial amount of cast iron water mains, lead water pipes and copper power cables amongst other disused structures was recovered and recycled. All remaining live services were identified and accurately marked out.

Result: A clean, safe and clearly identified site ready for redevelopment. With the advantage of recycling much needed metals and assets.

Advantage: The removal of toxic waste such as lead, disused open manholes repaired or removed. Opportunities for copper and metal theft substantially reduced.

Written by GLS

Inverbervie Rotor Radar Station. May 2025

Another site successfuly cleared of unwanted lead covered co-axle cable dating from the early 1950’s Cold war era.

Approximately 2 km of cable route consisting of multiple co-axle cables were recovered. This included the complex finding, identifying and recording of all live fibre and power cables feeding various live masts on the site, removing the disused cable routes resulted in the site being more user friendly for future developement, client extremely satisfied.

Written by GLS

Redundant cable removal.

We are pleased to be working with our client in the removal of the disused,old and unwanted underground cabling, After many years of operation these cables are disconnected and abandoned posing a logistic and environmental problem. GLS work closely with the client in removing any threat to the environment and creating a safe working area.

Written by GLS

Ottercops Chain Home 40

Ottercops Moss Chain Home radar station (CH.40) was located beside the A696 on the high ground halfway between the villages of Elsdon and Kirkwhelpington.

Built in June 1939, this vast site, consisting of four 360 feet tall steel transmitter towers positioned 180 feet apart, and four wooden receiver towers 240 feet tall, was one of the last Chain Home stations to become operational.

We identified and successfully recovered the following disused underground assets:

  1. 3 power cables serving 2 sets of radio towers
  2. A borehole for water to serve live water pipe
  3. Total cable recovered 18 tonnes with a content of 8 tonnes of lead, the rest was a mixture of copper and waste material.
  4. 38 locations where steel angle iron was protruding out of the ground. The reason being was due to the felling of the 4 360’ towers where the tops had embedded into the soft ground and could not be recovered at that time.
  5. Recovered 11 tonnes of steel.
  6. Field was subsequently rendered safe for use to the delight of the client.
  7. This legacy is important and the remaining evidence of this home chain station are the two underground reserves, both intact internally, their entrances have been made safe by large boulders to stop sheep falling into the chamber. aswell as inquisitive visitors.
Written by GLS

Backfilling Trenches and Other Excavations.

Backfill is the key to a solid and stable grading

September:2020 Airfield in SW England, 4 trenches x 1mtr deep, 2mtrs apart were completed. the Images demonstrate the importance of replacing the sub and top soil exactly where they came from within 30 mins of excavation and to ensure use of correct compaction rates. As you can see this method gives spectacular results within short period of time. By May 2021 no sign of previous activity, grass and nature back as before. Client delighted 😃

Written by GLS

Local Cell Corrosion (Differential Aeration)

A recent Completion of a contract by GLS  in SW England where 25km of trenching yielded 30 tonnes of corroded lead served cable, was recovered. Which clearly demonstrated a classic example of Differential aeration (Local Cell Corrosion) If left in the ground parts of the cable will degrade and enter the water course causing damage to the environment.Result: environmental cleanup.

Written by GLS

Kinetic Demolition Partnership

Gilmerton land Services and Kinetic demolition Edinburgh are pleased to announce their joint commitment to providing a streamlined business solution for our clients.

Written by GLS

Underground Cable wanted

GLS have just successfully completed a contract for the MOD at Eastriggs, Dumfriesshire raising significant funds for the organisation. Between now and next year when contracts with the MOD start again we are  looking to carry out work in the private sector.

If you are a Farmer, Land owner or House Builder or you simply own land that is ex MOD, there could be considerable valuable underground assets that have lain undetected for years which, if not removed can sometimes lead to the cause of a pathway of contamination.

GLS would be delighted to carry out a no-cost survey and on the discovery of any assets may be in a position to offer a credit.

If you would like to talk to us or are unsure of what you may have, do call one of our team on 01620 880207 or email: info@gilmertonlandsrvices.co.uk We would be delighted to hear from you.

Written by GLS

Narrow Gauge update

Apologies to those of you hoping to have confirmation today of access to the site at Eastriggs.

Unfortunately we are still at the mercy of  Health and Safety and it is not likely to be until the middle of nest week at the earliest now, possibly the week after. However as soon as we know we will announce.

Keep checking the blog and thanks everyone for your patience!

Written by GLS

Narrow Gauge Railway: Access Update.

Hi Everyone.

 

Unfortunately due to Health and Safety Issues access to the site at Eastriggs has been postponed until week beginning 22/02/2016. Apologies to those who were hoping to collect this week.

Will keep you updated on any further developments.